WAC 296-52-67230
Initiating systems.
(1) Electric systems.
(a) Safety switch. A safety switch must be:
(i) Placed at intervals in the permanent firing line when firing from a power circuit.
(ii) Made:
(A) So it can only be locked in the "off position"
OR
(B) With a short-circuiting arrangement of the firing lines to the detonator circuit
(b) Lighting gap. A lighting gap must be:
(i) At least five feet ahead (in the firing system) of the main firing switch, between the switch and power source.
(ii) Bridged by a flexible jumper cord just before firing the blast.